Usage:- For Biochemistry, Immunology and Serology tests.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-P | Plain Tube | 1-4ml | Red | 100 | 20 x 100 |
Usage :-These tubes are used for Biochemistry, Immunology and Serology tests. Gently invert the tube180° 8-10 times. The Sample will completely clot in 4-7 minutes.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-CA | Clot Activator | 1,2,3,4ml | Red | 100 | 20 x 100 |
Usage:- Used mainly in Hematology and testing whole blood in molecular diagnosis. EDTA tubes are used for direct sample analysis since erythrocytes, leucocytes and thrombocytes are stable in EDTA anti coagulated blood for 24 hours. Should gently invert 180° 8-10 times or roll in blood roller mixer to assure complete mixing with blood
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-K2 | K2-EDTA | 1,2,3,4ml | Lavender | 100 | 20 x 100 |
Usage:- Used mainly in Hematology and testing whole blood in molecular diagnosis. EDTA tubes are used for direct sample analysis since erythrocytes, leucocytes and thrombcytes are stable in EDTA anticoagulated blood for 24 hours. . Should gently invert 180° 8-10 times or roll in blood roller mixer to assure complete mixing with blood
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-K3 | K3-EDTA | 1,2,3,4ml | Violet | 100 | 20 x 100 |
Usage :- PT tube is used for blood coagulation tests like PT, PTT, TT, FDP and D-Dimer test. Mixing ratio is 1 part of Citrate to 9 parts of blood. Gently invert the tube 180° 3-4 times or roll in blood roller mixer to assure complete mixing with blood
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-Nac | NaCitrate | 0.9ml(1ml) 1.8ml(2ml) 2.7ml(3ml) | Blue | 100 | 20 x 100 |
These Tubes contain a Gel barrier at the bottom . The specific gravity of this material can make the barrier gel move upward to the serum-clot interface during centrifugation and it forms a stable barrier separating serum from fibrin cells. This barrier provides stability of certain parameters of the tubes under the recommended conditions for up to 48 hours. Gently invert the tube180° 8-10 times and after coagulation, centrifuge at 2000-3000 rpm for 10 min. at room temperature. Used in Bio Chemistry, Immunology and serology. Antibody screening, Indirect and Direct methods.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-GEL | Gel Tube | 1,2,3,4ml | Yellow | 100 | 20 x 100 |
These tubes are spray coated with Lithium Heparin. Heparin activates anti thrombins, thus blocking the coagulation cascade and produce a plasma sample Gently invert the tubes 180° 5-8 times immediately after blood collection or mix in roller mixer. Centrifuge at 2000-3000 rpm for 10 min. at room temperature. Used for emergency Biochemistry test, Endocrine and metabolic disorders, Therapeutic Drug monitoring and Toxicology, Electrolytes, Clinical chemistry, Serology and immunology etc. Lithium test should not be performed using Lithium Heparin tubes.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-LH | Lithium Heparin | 1,2,3,4ml | Green | 100 | 20 x 100 |
Sodium Heparin is coated to inhibit clotting. Heparin activates anti thrombins, thus blocking the coagulation cascade, produce a plasma sample. Gently invert the tubes 180° 5-8 times immediately after blood collection or mix using roller mixer. Used for emergency Biochemistry test, but also for Endocrine and metabolic disorders, Therapeutic Drug monitoring and Toxicology, Electrolytes, Clinical chemistry, Serology and immunology etc. Centrifuge at 2000-3000 rpm for 10 min. at room temperature.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-G | Glucose | 1,2,3,4ml | Grey | 100 | 20 x 100 |
Usage:- ESR tube is used for Erythrocytes sedimentation rate test as per Westergren method. These tubes contain buffered Tri-Sodium provided in 3.8%.. Mixing ratio 1:4
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-NAC(E) | Nac 3.8% | 1.6ml(2ml) | Black | 100 | 20 x 100 |
Glucose tube is used in blood tests such as blood sugar, glucose tolerance and Lactate tests. Mix gently by inversion 180° 8-10 times after adding blood or using a roller mixer.
Code | Product | Volume | Cap Colour | Pack | Box |
---|---|---|---|---|---|
SLD-CA | Clot Activator | 1,2,3,4ml | Red | 100 | 20 x 100 |
Office No – 404, Concord Premises, Plot No – 66A, Sector – 11, CBD Belapur, Navi Mumbai, Maharashtra – 400614.
Office no-27, Building no-851, Way no-4011, Near Al Raffah Hospital, Al Ghubrah, Muscat, Sultanate of Oman
Plot No -119-0 - Dubai Investments Park 1st Office -107 - 0142 Dubai UAE.